![](https://nerve-sensors.com/wp-content/uploads/2024/09/1-1024x614.jpg)
Heightened Sensitivities – Rędziński Bridge
Structural Health Monitoring (SHM) is increasingly being used on strategically important structures. In 2020, EpsilonRebars…
![](https://nerve-sensors.com/wp-content/uploads/2024/09/2-e17269961236459.jpg)
Fibre optics a breakthrough in measurements
Application of distributed fibre optic sensing (DFOS) offers completely new capabilities in condition assessment of…
![](https://nerve-sensors.com/wp-content/uploads/2021/04/Obraz222-e1619622447970-1.jpg)
Distributed optical fibre sensors for strain and temperature monitoring of early-age concrete: laboratory and in situ examples
The article presents the very new measuring tools which allow for comprehensive analysis of concrete…
![](https://nerve-sensors.com/wp-content/uploads/2024/09/98.jpg)
Distributed fibre optic sensors in civil engineering applications – selected case studies in Poland
The article provides a brief overview of pilot projects employing the DFOS technique with monolithic…
![](https://nerve-sensors.com/wp-content/uploads/2022/05/lid1-1.png)
Distributed fibre optic sensing: reinforcement yielding strains and crack detection in concrete slab during column failure simulation
The structural behaviour of the RC slab-column structure was controlled using advanced measurement techniques, including…
![](https://nerve-sensors.com/wp-content/uploads/2022/12/bridge6-1.jpg)
Distributed fibre optic sensing for safety monitoring of concrete, steel and composite bridges
The article briefly discusses possible solutions available on the market, indicating their specific advantages and…
![](https://nerve-sensors.com/wp-content/uploads/2024/06/crack-detection.jpg)
Distributed Fibre Optic Nerve-Sensors as non-destructive tool for crack detection and widths estimation
The article describes the design of unique composite Nerve-Sensors dedicated to civil engineering and geotechnical…
![](https://nerve-sensors.com/wp-content/uploads/2021/04/20190913_130150-1-scaled-e1626701931908.jpg)
DFOS measurements for strain analysis of anchorage zone in 57-year-old posttensioned precast girder using static and high-frequency approach
The article presents the results of static and high-frequency strain measurements of a 57-year-old post-tensioned…
![](https://nerve-sensors.com/wp-content/uploads/2024/09/29.jpg)
Cracks Detection During Early-Age Concrete Hydration Using Distributed Fibre Optic Sensing: From Laboratory to Field Applications
The article summarises the recent examples of DFOS as a non-destructive approach to crack detection, especially…